Historic Masonry and Grouting Mortar MG II, fine, 25 kg

Article Number
4263202
€22.85 €19.20
Base Price: €0.77 / 1 kg 19 % VAT excl. (All prices without shipping)
Availability:
2 - 3 days
Weight: 25.0000 kg
Select your Wishlist:
Please select a wishlist or create one here
Select your Project:
Please select a project or create one here
CAS-Number: 85117- 09-5 / 1317- 65-3
Danger
H315, H318
Safety Instructions:
P102, P280, P305+P351+P338+P315, P302+P352, P261+P304+P340, P501

HISTOCAL®

Otterbein MG II Mörtelgruppe / mortar group: M 2,5, EN 998-2, NM IIa, DIN V 18580.

Feine Körnung / grain size fine: 0 - 2 mm.

Based on natural hydraulic lime. For masonry and grouting.

Composition

Otterbein HMF - MG II consists of na tural hydraulic lime NHL 5 acc. to EN 459-1 and grain-classified crushed lime sands.

Properties

  • grading curve accordi ng to historic findings
  • free from cement and synthetic additives
  • high natural water re tention properties
  • very good side adhesion
  • highly permeable
  • low-tension hardening process
  • low E-module - high elasticity

Application

For laying bricks and grouting of hist oric masonry (e.g. natural stones, bricks). Historic Masonry- and Grouting Mortar MG IIa is recommended in case of buildings subjected to humidity.

Substrate

The substrate must be dry, clean and free from loosely attached particles. Sufficiently wet absorbing masonry before.

Processing

To be processed with all commonly used mortar mixers (continuous mixer, gravity mixer, blunger) and by hand. Watch for uniform and correct consistency (well earth-moist to plastic).

New construction of masonry: For the simultaneous bricklaying and grouting.

Subsequent grouting to re novate existing masonry:
Scrape out joints and clean.
Working procedure acc. to DIN:
1st working step: first vertical joint, then horizontal joint
2nd working step: first horizontal joint, then vertical joint
Joint finishing through smooth finish or broom finish.

After-treatment

Protect fresh mortar until sufficient hardening (usually several weeks) against premature dryi ng-out through sun radiation and draft (e.g. hinge with jute sheets kept moist or spray with mist nozzles). The mortar must be protected against frost for several weeks until sufficient hardening has been achieved!

Special notes

The air- and surface temperature mu st al least amount to 5 °C during processing. Otterbein HMF - MG II shall only be used in the original state without additives.

Storage

Dry, if possible on wooden shelves and protected against draft. Storage time shall not exceed 6 months.

Technical data

Mortar group: M 2.5 acc. to EN 998-2 NMII acc. to DIN V 18580
Grain size: 0 - 1.6 mm or 0 - 4 mm
Solid mortar raw density: approx.1.65 kg/dm³
Compressive strength 28 days: approx. 2,5 N/mm²
Flexural strength 28 da ys: approx. 1,0 N/mm²
E-Module: approx. 3,5 kN/mm²

Safety instructions

Mortal will react very alkaline with water, thus: Protect skin and eyes, rinse thoroughly with water in ca se of contact, immediately contact doctor in case of eye contact.